MEDIUMvisual defectElectrical Panel 12 · high criticality · Turbine Hall NorthHidden in COMPLETEDM026 · 09-10 02:02
What Spot saw
Action
visual inspection
Result
OK
Reading
98 score · good quality
Battery
79%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
5 in the kit
Anomalies at this location
2 in the kit
Location success rate
86% (12/14)
Why this needs you
Medium visual defect on Electrical Panel 12, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
MEDIUMsignal degradationHeat Exchanger 19 · medium criticality · Warehouse CorridorHidden in COMPLETEDM027 · 09-10 10:15
What Spot saw
Action
navigation
Result
OK
Reading
None recorded
Battery
73%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
1 in the kit
Anomalies at this location
1 in the kit
Location success rate
MEDIUMabnormal vibrationPump 05 · medium criticality · Valve StationHidden in COMPLETEDM020 · 09-08 02:20
What Spot saw
Action
acoustic inspection
Result
OK
Reading
64.8 dB · good quality
Battery
70%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
MEDIUMnavigation obstructionHeat Exchanger 04 · medium criticality · Pipe GalleryHidden in COMPLETEDM020 · 09-08 02:02
What Spot saw
Action
navigation
Result
Failed, localization failure
Reading
53.7 pct · questionable quality
Battery
84%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
8 in the kit
Location success rate
MEDIUMvisual defectHeat Exchanger 10 · medium criticality · Battery RoomHidden in COMPLETEDM015 · 09-06 10:06
What Spot saw
Action
visual inspection
Result
OK
Reading
92 score · good quality
Battery
67%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
3 in the kit
Location success rate
MEDIUMabnormal temperatureElectrical Panel 18 · medium criticality · Inspection DockHidden in COMPLETEDM012 · 09-05 10:21
What Spot saw
Action
thermal inspection
Result
Failed, sensor timeout
Reading
63 C · questionable quality
Battery
24%
Sample image from NextEra's kit (synthetic), not this exact capture
Medium signal degradation on Heat Exchanger 19, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
Medium abnormal vibration on Pump 05, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
Medium navigation obstruction on Heat Exchanger 04, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (localization failure), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
Medium visual defect on Heat Exchanger 10, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
Medium abnormal temperature on Electrical Panel 18, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.