15 need you (4 critical) · 40 found across 27 missions · ranked by severity, then asset criticality
Anomalies at this location
2 in the kit
Location success rate
86% (12/14)
Why this needs you
Medium visual defect on Electrical Panel 12, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
MEDIUMsignal degradationHeat Exchanger 19 · medium criticality · Warehouse CorridorHidden in COMPLETEDM027 · 09-10 10:15
What Spot saw
Action
navigation
Result
OK
Reading
None recorded
Battery
73%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
1 in the kit
Anomalies at this location
1 in the kit
Location success rate
100% (16/16)
Why this needs you
Medium signal degradation on Heat Exchanger 19, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal vibrationPump 05 · medium criticality · Valve StationHidden in COMPLETEDM020 · 09-08 02:20
What Spot saw
Action
acoustic inspection
Result
OK
Reading
64.8 dB · good quality
Battery
70%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
92% (11/12)
Why this needs you
Medium abnormal vibration on Pump 05, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
MEDIUMnavigation obstructionHeat Exchanger 04 · medium criticality · Pipe GalleryHidden in COMPLETEDM020 · 09-08 02:02
What Spot saw
Action
navigation
Result
Failed, localization failure
Reading
53.7 pct · questionable quality
Battery
84%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Medium navigation obstruction on Heat Exchanger 04, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (localization failure), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMvisual defectHeat Exchanger 10 · medium criticality · Battery RoomHidden in COMPLETEDM015 · 09-06 10:06
What Spot saw
Action
visual inspection
Result
OK
Reading
92 score · good quality
Battery
67%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
3 in the kit
Location success rate
91% (20/22)
Why this needs you
Medium visual defect on Heat Exchanger 10, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal temperatureElectrical Panel 18 · medium criticality · Inspection DockHidden in COMPLETEDM012 · 09-05 10:21
What Spot saw
Action
thermal inspection
Result
Failed, sensor timeout
Reading
63 C · questionable quality
Battery
24%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
69% (11/16)
Why this needs you
Medium abnormal temperature on Electrical Panel 18, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMvisual defectHeat Exchanger 08 · medium criticality · Cooling LoopHidden in COMPLETEDM006 · 09-03 10:21
What Spot saw
Action
visual inspection
Result
Failed, reading unreliable
Reading
90 score · questionable quality
Battery
32%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
73% (11/15)
Why this needs you
Medium visual defect on Heat Exchanger 08, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMgauge out of rangeElectrical Panel 11 · medium criticality · Turbine Hall SouthHidden in COMPLETEDM004 · 09-02 18:24
What Spot saw
Action
gauge reading
Result
Failed, sensor timeout
Reading
68.6 psi · questionable quality
Battery
38%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
Medium gauge out of range on Electrical Panel 11, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal vibrationElectrical Panel 11 · medium criticality · Turbine Hall SouthHidden in COMPLETEDM002 · 09-02 02:18
What Spot saw
Action
acoustic inspection
Result
Failed, reading unreliable
Reading
66.6 dB · questionable quality
Battery
48%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
Medium abnormal vibration on Electrical Panel 11, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMlocalization issueElectrical Panel 15 · low criticality · Main EntranceHidden in COMPLETEDM024 · 09-09 10:07
What Spot saw
Action
navigation
Result
Failed, obstacle detection
Reading
49.2 pct · questionable quality
Battery
78%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
85% (17/20)
Why this needs you
Medium localization issue on Electrical Panel 15, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (obstacle detection), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal temperatureElectrical Panel 15 · low criticality · Turbine Hall NorthHidden in COMPLETEDM012 · 09-05 10:24
What Spot saw
Action
thermal inspection
Result
Failed, reading unreliable
Reading
82.8 C · questionable quality
Battery
19%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
4 in the kit
Anomalies at this location
2 in the kit
Location success rate
86% (12/14)
Why this needs you
Medium abnormal temperature on Electrical Panel 15, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal vibrationElectrical Panel 15 · low criticality · Main EntranceHidden in COMPLETEDM008 · 09-04 02:15
What Spot saw
Action
acoustic inspection
Result
Failed, reading unreliable
Reading
77.5 dB · questionable quality
Battery
37%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
85% (17/20)
Why this needs you
Medium abnormal vibration on Electrical Panel 15, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
MEDIUMabnormal vibrationElectrical Panel 15 · low criticality · Main EntranceHidden in COMPLETEDM006 · 09-03 10:15
What Spot saw
Action
acoustic inspection
Result
Failed, sensor timeout
Reading
67.7 dB · questionable quality
Battery
44%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
85% (17/20)
Why this needs you
Medium abnormal vibration on Electrical Panel 15, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
3 in the kit
Anomalies at this location
2 in the kit
Location success rate
69% (11/16)
Why this needs you
Medium abnormal temperature on Heat Exchanger 01, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (target not detected), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWsignal degradationElectrical Panel 12 · high criticality · Electrical RoomHidden in COMPLETEDM025 · 09-09 18:14
What Spot saw
Action
navigation
Result
OK
Reading
97.1 pct · good quality
Battery
76%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
5 in the kit
Anomalies at this location
3 in the kit
Location success rate
69% (9/13)
Why this needs you
Low signal degradation on Electrical Panel 12, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot did not flag it; acknowledge or dismiss.
LOWabnormal temperaturePressure Gauge 09 · high criticality · Electrical RoomHidden in COMPLETEDM012 · 09-05 10:27
What Spot saw
Action
thermal inspection
Result
Failed, reading unreliable
Reading
None recorded
Battery
13%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
1 in the kit
Anomalies at this location
3 in the kit
Location success rate
69% (9/13)
Why this needs you
Low abnormal temperature on Pressure Gauge 09, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWgauge out of rangeHeat Exchanger 08 · medium criticality · Control Room CorridorHidden in COMPLETEDM025 · 09-09 18:16
What Spot saw
Action
gauge reading
Result
Failed, sensor timeout
Reading
117.7 psi · questionable quality
Battery
74%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
89% (16/18)
Why this needs you
Low gauge out of range on Heat Exchanger 08, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWgauge out of rangeHeat Exchanger 08 · medium criticality · Cooling LoopM017 · 09-07 02:24
What Spot saw
Action
gauge reading
Result
Failed, target not detected
Reading
124.2 psi · questionable quality
Battery
28%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
73% (11/15)
Why this needs you
Low gauge out of range on Heat Exchanger 08, a medium criticality asset. The inspection itself failed (target not detected), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWabnormal vibrationCompressor 14 · medium criticality · Pump BayHidden in COMPLETEDM015 · 09-06 10:20
What Spot saw
Action
acoustic inspection
Result
Failed, sensor timeout
Reading
59.8 dB · questionable quality
Battery
47%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
1 in the kit
Anomalies at this location
1 in the kit
Location success rate
78% (14/18)
Why this needs you
Low abnormal vibration on Compressor 14, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWsignal degradationElectrical Panel 03 · medium criticality · Pipe GalleryHidden in COMPLETEDM015 · 09-06 10:03
What Spot saw
Action
navigation
Result
Failed, localization failure
Reading
59.5 pct · questionable quality
Battery
72%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low signal degradation on Electrical Panel 03, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (localization failure), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWabnormal vibrationElectrical Panel 03 · medium criticality · Pipe GalleryHidden in COMPLETEDM007 · 09-03 18:27
What Spot saw
Action
acoustic inspection
Result
Failed, sensor timeout
Reading
70.5 dB · questionable quality
Battery
25%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low abnormal vibration on Electrical Panel 03, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWnavigation obstructionHeat Exchanger 04 · medium criticality · Pipe GalleryHidden in COMPLETEDM004 · 09-02 18:03
What Spot saw
Action
navigation
Result
Failed, communication loss
Reading
66.2 pct · questionable quality
Battery
76%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low navigation obstruction on Heat Exchanger 04, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (communication loss), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
LOWabnormal temperatureHeat Exchanger 04 · medium criticality · Pipe GalleryHidden in COMPLETEDM003 · 09-02 10:25
What Spot saw
Action
thermal inspection
Result
Failed, target not detected
Reading
51.7 C · questionable quality
Battery
23%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low abnormal temperature on Heat Exchanger 04, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (target not detected), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
3 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low signal degradation on Heat Exchanger 01, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (localization failure), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
low
Anomalies on this asset
3 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Low navigation obstruction on Heat Exchanger 01, a low criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (obstacle detection), so the reading may not be trustworthy. Spot did not flag it; acknowledge or dismiss.