15 need you (4 critical) · 40 found across 27 missions · ranked by severity, then asset criticality
Anomalies on this asset
5 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
Critical navigation obstruction on Electrical Panel 12, a high criticality asset. The inspection itself failed (communication loss), so the reading may not be trustworthy. Decide on a work order before the next round.
CRITICALabnormal temperatureHeat Exchanger 04 · medium criticality · Control Room CorridorHidden in COMPLETEDM020 · 09-08 02:08
What Spot saw
Action
thermal inspection
Result
OK
Reading
41.4 C · good quality
Battery
80%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
89% (16/18)
Why this needs you
Critical abnormal temperature on Heat Exchanger 04, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Decide on a work order before the next round.
CRITICALsignal degradationElectrical Panel 03 · medium criticality · Pipe GalleryHidden in COMPLETEDM007 · 09-03 18:02
What Spot saw
Action
navigation
Result
Failed, localization failure
Reading
49.2 pct · questionable quality
Battery
74%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
8 in the kit
Location success rate
74% (32/43)
Why this needs you
Critical signal degradation on Electrical Panel 03, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (localization failure), so the reading may not be trustworthy. Decide on a work order before the next round.
CRITICALgauge out of rangeElectrical Panel 11 · medium criticality · Turbine Hall SouthHidden in COMPLETEDM006 · 09-03 10:31
What Spot saw
Action
gauge reading
Result
Failed, reading unreliable
Reading
111.6 psi · questionable quality
Battery
15%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
Critical gauge out of range on Electrical Panel 11, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Decide on a work order before the next round.
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
critical
Anomalies on this asset
1 in the kit
Anomalies at this location
3 in the kit
Location success rate
69% (9/13)
Why this needs you
High abnormal vibration on Heat Exchanger 02, a critical criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHgauge out of rangeHeat Exchanger 17 · critical criticality · Compressor AreaHidden in COMPLETEDM014 · 09-06 02:07
What Spot saw
Action
gauge reading
Result
Failed, sensor timeout
Reading
128.8 psi · questionable quality
Battery
54%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
critical
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
88% (15/17)
Why this needs you
High gauge out of range on Heat Exchanger 17, a critical criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot flagged it for operator review.
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
critical
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
88% (15/17)
Why this needs you
High localization issue on Heat Exchanger 17, a critical criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot flagged it for operator review.
HIGHvisual defectElectrical Panel 12 · high criticality · Turbine Hall SouthHidden in COMPLETEDM016 · 09-06 18:26
What Spot saw
Action
visual inspection
Result
Failed, reading unreliable
Reading
74 score · questionable quality
Battery
19%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
5 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
High visual defect on Electrical Panel 12, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (reading unreliable), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHabnormal vibrationHeat Exchanger 13 · high criticality · Control Room CorridorHidden in COMPLETEDM015 · 09-06 10:23
What Spot saw
Action
acoustic inspection
Result
Failed, signal noise
Reading
None recorded
Battery
42%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
1 in the kit
Anomalies at this location
3 in the kit
Location success rate
89% (16/18)
Why this needs you
High abnormal vibration on Heat Exchanger 13, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (signal noise), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHgauge out of rangeElectrical Panel 12 · high criticality · Turbine Hall SouthHidden in COMPLETEDM014 · 09-06 02:05
What Spot saw
Action
gauge reading
Result
Failed, sensor timeout
Reading
None recorded
Battery
59%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
high
Anomalies on this asset
5 in the kit
Anomalies at this location
6 in the kit
Location success rate
64% (14/22)
Why this needs you
High gauge out of range on Electrical Panel 12, a high criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHabnormal vibrationHeat Exchanger 10 · medium criticality · Battery RoomHidden in COMPLETEDM025 · 09-09 18:12
What Spot saw
Action
acoustic inspection
Result
Failed, signal noise
Reading
64.7 dB · questionable quality
Battery
78%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
3 in the kit
Location success rate
91% (20/22)
Why this needs you
High abnormal vibration on Heat Exchanger 10, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (signal noise), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHabnormal vibrationPump 05 · medium criticality · Valve StationHidden in COMPLETEDM024 · 09-09 10:05
What Spot saw
Action
acoustic inspection
Result
Failed, sensor timeout
Reading
79.6 dB · questionable quality
Battery
82%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
2 in the kit
Anomalies at this location
2 in the kit
Location success rate
92% (11/12)
Why this needs you
High abnormal vibration on Pump 05, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHsignal degradationElectrical Panel 18 · medium criticality · Heat Exchanger AreaHidden in COMPLETEDM022 · 09-08 18:07
What Spot saw
Action
navigation
Result
Failed, communication loss
Reading
None recorded
Battery
81%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
2 in the kit
Anomalies at this location
1 in the kit
Location success rate
93% (13/14)
Why this needs you
High signal degradation on Electrical Panel 18, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (communication loss), so the reading may not be trustworthy. Spot flagged it for operator review.
HIGHvisual defectHeat Exchanger 10 · medium criticality · Battery RoomHidden in COMPLETEDM009 · 09-04 10:12
What Spot saw
Action
visual inspection
Result
OK
Reading
96 score · good quality
Battery
47%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
3 in the kit
Anomalies at this location
3 in the kit
Location success rate
91% (20/22)
Why this needs you
High visual defect on Heat Exchanger 10, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. Spot flagged it for operator review.
HIGHvisual defectHeat Exchanger 08 · medium criticality · Cooling LoopHidden in COMPLETEDM001 · 09-01 18:27
What Spot saw
Action
visual inspection
Result
Failed, sensor timeout
Reading
75 score · questionable quality
Battery
22%
Sample image from NextEra's kit (synthetic), not this exact capture
Context
Asset criticality
medium
Anomalies on this asset
4 in the kit
Anomalies at this location
3 in the kit
Location success rate
73% (11/15)
Why this needs you
High visual defect on Heat Exchanger 08, a medium criticality asset. Its mission still reported COMPLETED, so mission status will not show this. The inspection itself failed (sensor timeout), so the reading may not be trustworthy. Spot flagged it for operator review.